Expert Gas Leak & Flame Detection System Installation for Commercial & Industrial Projects
In high-risk environments, early gas and flame detection can prevent catastrophic loss. At Brismek, we specialize in the design and installation of gas leak and flame detection systems for industrial and commercial applications across the Delhi NCR region, with operational headquarters in Noida. Our solutions are engineered for environments where flammable or toxic gases are stored, used, or processed. From manufacturing plants and gas banks to refineries and commercial kitchens, we install high-sensitivity gas detectors and flame detection systems that ensure fast response and seamless integration with fire safety infrastructure. Brismek is experienced in deploying top-tier detection technologies from Honeywell, MSA, Dräger, Ambetronics, and other trusted OEMs.
Why Professional Gas & Flame Detection Systems Matter
Gas and flame detection systems are essential to life safety, asset protection, and regulatory compliance. A professionally installed detection system helps you:
Detect leaks of flammable, combustible, or toxic gases before they reach dangerous levels
Identify open flames instantly using IR or UV/IR detection for fast mitigation
Comply with regulations from PESO, OISD, NFPA, NBC, and factory inspection authorities
Integrate alarms with ventilation shutdown, suppression, and emergency protocols
Protect employees, processes, and infrastructure from fire, explosion, or exposure risks
Secure fire NOCs and reduce insurance premiums through preventive infrastructure
Our Gas & Flame Detection System Installation Services
Brismek delivers comprehensive gas leak and flame detection systems, engineered for your building's unique risk profile and environment.
Systems We Install
Fixed Gas Detectors:
Combustible (LEL), Toxic (CO, H₂S, NH₃, Cl₂), and Oxygen deficiency sensors
Infrared (IR), Catalytic bead, Electrochemical, and PID-based technologies
Portable Gas Detectors (on request for specialized industries)
Flame Detection Systems:
IR, UV, and UV/IR combination detectors for open flame detection
Explosion-proof housings and fast-response digital models
Controller Panels:
Multi-channel control panels with alarm relays, sounders, and HMI display
Integration with fire alarm systems, suppression panels, and BMS
Supported Brands
Honeywell, MSA, Dräger, Riken Keiki (International)
Ambetronics, Three S Instruments, Multispan, and other Indian OEMs
Industries We Serve
Oil & gas terminals and LPG filling stations
Pharma and chemical manufacturing plants
Food & beverage processing units and cold storage
Commercial kitchens, malls, and hospitals
Data centers, utilities, and telecom installations
Powerhouses, substations, and transformer yards
Customization Options
Area classification for hazardous zones (Zone 1/Zone 2)
Explosion-proof and weather-proof detectors (ATEX/IECEx certified)
Gas sampling systems for pressurized or enclosed areas
Multi-zone alarm architecture and logic-based actuation
Multi-brand integration with suppression and alarm systems
Our Process – How It Works
We follow a precise, compliant process from design to commissioning to ensure safety and reliability:
Site Risk Assessment – Hazardous gases and ignition sources are mappedSystem Design – Customized layouts based on gas type, ventilation, and zoningInstallation – Sensors, piping, flame detectors, and controllers are installed to codeIntegration – Systems are integrated with suppression, alarms, or HVAC controlsTesting & Calibration – Factory-specified calibration using certified gas kitsDocumentation & Handover – System diagrams, manuals, and user training provided
Why Choose Brismek
Located in Noida with service coverage across Delhi NCR
15+ years of experience in industrial gas detection and fire safety systems
Trained engineers for Honeywell, MSA, Dräger, Ambetronics, and more
Installation as per PESO, NFPA, BIS, and factory safety compliance
Seamless integration with fire panels, suppression, and safety PLCs
Preferred partner for MEP consultants, industrial safety heads, and facility managers
Frequently Asked Questions
What types of gases can you detect?We provide detection for a wide range including LPG, methane, ammonia, CO, H₂S, oxygen deficiency, chlorine, and more.
Are flame detectors necessary along with gas leak detectors?Yes, especially in Zone 1 and Zone 2 hazardous areas, combining both enhances safety by covering leak detection and actual flame presence.
Do these systems need regular calibration?Absolutely. Gas sensors must be calibrated every 6 to 12 months as per OEM guidelines to ensure accuracy.
Can I integrate gas detection with my existing fire alarm or suppression system?Yes. We provide seamless integration with fire alarm panels, BMS, suppression control, and relay-based shutdown systems.
What’s the difference between IR, UV, and UV/IR flame detectors?IR detects radiant heat from flames; UV detects ultraviolet light; UV/IR combines both, offering higher immunity to false alarms and faster flame detection.