About
Expert Room Integrity Test Service for Fire Suppression Systems
A fire suppression system is only as effective as the room it protects. At Brismek, we provide certified Room Integrity Testing (RIT) using industry-leading Retrotec equipment to verify the airtightness of enclosures protected by clean agent systems like Novec 1230, FM-200, Inert Gas, and CO₂ flooding systems. Serving clients across Delhi NCR from our hub in Noida, our Room Integrity Tests ensure that the protected area will hold the fire suppression agent long enough to suppress the fire effectively, as mandated by NFPA 2001 and ISO 14520 standards. Whether you're maintaining a data center, electrical panel room, or server facility, Brismek helps you stay compliant, safe, and audit-ready.
Why Room Integrity Testing Matters
Fire suppression systems are highly dependent on room sealing. Without a certified Room Integrity Test, your clean agent system may fail during an actual fire event. Here's why this service is essential:
Ensures compliance with NFPA, IS 15493, and ISO 14520 guidelines
Validates agent hold time (typically 10 minutes) for effective fire suppression
Required for annual system recertification and insurance validation
Prevents agent leakage and system inefficiency
Avoids costly downtime and equipment damage in sensitive zones
Reduces risk of fire damage in high-value, mission-critical rooms
Our Room Integrity Testing Service
Using calibrated and globally accepted Retrotec Door Fan Testing Equipment, Brismek conducts professional Room Integrity Tests for a wide range of fire-protected enclosures.
What We Test
Server Rooms and Data Centers
Electrical and UPS Rooms
Telecom and Control Rooms
Archives and Document Storage Areas
Substations and Switchgear Rooms
Clean Rooms and Lab Environments
Industrial Equipment Enclosures protected by clean agents
Our Testing Process
Air tightness measurement of the protected room using Retrotec blower door systems
Calculation of leakage rate and hold time for the specific suppression agent
Identification of leakage points for corrective action
Comprehensive report with pass/fail status and retention time documentation
Retesting (if needed) after leakage rectification
Certification for submission to fire safety auditors and insurers
Complies With
NFPA 2001 (Standard on Clean Agent Fire Extinguishing Systems)
ISO 14520 (Gaseous Fire-Extinguishing Systems)
OEM guidelines from manufacturers of Novec 1230, FM-200, Inergen, IG-541, and CO₂ systems
Our Process – How It Works
We follow a methodical approach to ensure accurate testing and detailed reporting:
Initial Site Inspection – Evaluate room readiness and suppression system setupSetup of Retrotec Fan & Sensors – Install calibrated test equipment at the enclosure’s main doorwayPressurization & Measurement – Simulate fire suppression discharge to calculate pressure retentionData Collection & Analysis – Software-driven analysis of leakage rate and retention timeReport Submission – Receive a certified report with results, diagrams, and recommendationsSupport for Rectification & Retest – Optional sealing service or retesting to meet compliance
Why Choose Brismek
Based in Noida, with services available across Delhi NCR
15+ years of fire suppression and clean agent compliance expertise
Use of Retrotec, the global standard in integrity testing equipment
Compliance with national and international safety codes
Trusted by IT parks, data centers, telecom providers, and facility managers
Timely service, accurate reporting, and complete documentation support
Frequently Asked Questions
What is a Room Integrity Test?It’s a test to ensure that a protected room can hold the fire suppression agent for a required time (usually 10 minutes) to suppress a fire effectively.
Is the test mandatory for clean agent systems?Yes. As per NFPA 2001 and ISO 14520, RIT is required during system commissioning and annually thereafter.
What if the room fails the integrity test?We provide detailed leakage reports so your team can fix sealing issues. We also offer retesting and sealing guidance.
How long does the test take?Most tests are completed within 2–3 hours, including setup, measurement, and reporting.
Can you provide this service after business hours?Yes. We offer flexible scheduling to avoid disruption in live data centers and operational environments.